EMAIL:info@yuy-precision.com

Removable Element Woltman Flange Water Meter LXLC-350~600E

Removable Element Woltman Flange Water Meter LXLC-350~600E

Removable Element Woltman Flange Water Meter LXLC-350~600E

FEATURE:

1.Removable element structure, easy installation and maintenance, register for universal use within this range detachable without Removing the meter from the pipeline;

2. Dry-dial, Magnetic drive sensitive action, small pressure loss;

3. Vacuum sealed register ensures the dial keep free from fog and Keep the reading clear in a long term service;

4. Selected high quality materials for steady & reliable characteristic;

5. Technical data conform to international standard ISO 4064 Class B

6. Can be with reed switch (optional)

.

WORKING CONDITION

Water temperature: 0.1 ºC~50 ºC  (0.1 ºC~90 ºC for hot water meter)

Water pressure: ≤1.0Mpa (1.6MPa for special requirement)


Detailed information

Main Technical Data

DN (mm)

Class

Qmax

Qn

Qt

Qmin

Min. reading

Max. reading

m3/h

l/h

m3

50

A

30

15

4.5

1.2

0.0002

999,999

B

3

0.45

65

A

50

25

7.5

2

0.0002

999,999

B

5

0.75

80

A

80

40

12

3.2

0.002

999,999

B

8

1.2

100

A

120

60

18

4.8

0.002

999,999

B

12

1.8

125

A

200

100

30

8

0.002

999,999

B

20

3

150

A

300

150

45

12

0.002

999,999

B

30

4.5

200

A

500

250

75

20

0.002

999,999

B

50

7.5

250

A

800

400

120

32

0.002

999,999

B

80

12

300

A

1200

600

180

48

0.02

9,999,999

B

120

18

400

B

2000

1000

200

30

0.02

9,999,999

500

B

3000

1500

300

45

0.02

9,999,999

Maximum Permissible Error:

      In the lower zone from Qmin inclusive up to but excluding Qt is  ±5%

  In the upper zone from Qt inclusive up to and including Qmax is ±2% ( ±3% for hot water )


Dimensions and Weights

35d85eee-6c1d-4a9b-a1cc-dbe4f6399709.png

Size

Length L

Height H

Outer Diameter D1

Bolt Circle Diameter D2

Connecting Bolt

Weight

mm





n-Md

Kg

50

200

247

165

125

4-M16

8

65

200

260

185

145

4-M16

13

80

225

265

200

160

8-M16

15

100

250

272

220

180

8-M16

19

125

250

295

250

210

8-M16

23

150

300

302

285

240

8-M20

30

200

350

359

340

295

8-M20(1.0MPa)

42

12-M20(1.6MPa)

41.5

250

450

470

395

350

12-M20(1.0MPa)

77

405

355

12-M24(1.6MPa)

79

300

500

492

445

400

12-M20(1.0MPa)

97

460

410

12-M24(1.6MPa)

114

400

600

631

565

515

16-M24(1.0MPa)

199

580

525

16-M27(1.6MPa)

206

500

800

740

670

620

20-M24(1.0MPa)

340

715

650

20-M30(1.6MPa)

358

 NOTE: The flange dimension conforms to ISO7005-2:1988 standard. Order for products of special requirements is also accepted.



 


Please Attention:

1.If you want to get samples and catalogue from us, please contact us at info@yuy-precision.com  Normally, we need 7-15 days for making samples. and you need to pay for them. However, it would be highly appreciated if you can accept freight collect.
2.We normally need 20-35 days for production,however,please contact us if urgent
3.We ar OEM,ODM supplier,Wesupport FOB,CFR,DIF price term, and often ship from SHANGHAI or NINGBO sea port.
4.We encourage payment term:T/T or irrevocable L/C at sight, or 30% T/T deposit and 70% balance when receipt of advice of shipment.
5.Before installing the meter, we had better make sure that, it has been chosen correctly, check that the nominal diameter, flow rate, working temperature and pressure are compatible with the installation conditions.




BACK PREVIOUS NEXT

Contact


Enquiry