COMBINATION FLANGE WATER METER LXF 50~200

COMBINATION FLANGE WATER METER LXF 50~200

LXF-50~200   COMBINATION FLANGE WATER METER

APPLICATION

For measurement of high flows of cold potable water passing through the pipeline.

 

FEATURES

1. Wide measuring range: From Qmin of the small caliber water meter to Qmax of the large caliber water meter

2. As a dry meter, deposits in the register are avoided. This ensures a clear reading in long term service.

4. Low head loss.

5. Lower starting flow.

6. Novel structure, simple maintenance.   

7. Can be equipped with reed switch option.

8. Particularly suited in commercial, institutional places of assembly and facilities with fluctuating usage and flow rates.

 

CONSTRUCTION

The meter model LXF 50~200 combines a large caliber water meter (Model LXLC)

on the main line, a small water meter (Model LXSG) on the bypass line, and a flow

changeover valve.

Annotation: LXLC removable element woltman water meter

         LXSG multi-jet dry type vane wheel water meter

         (LXSY multi-jet liquid sealed type vane wheel water meter)

WORKING CONDITION

Water temperature: ≤ 50 OC

Water pressure:≤1.0 Mpa  (1.6MPa on request)

 


Detailed information

INSTALLATION

1. The meter must be installed with the direction of the flow as indicated by the arrow cast in the meter body.

2. A horizontal position with the register face upwards is recommended.

3. The meter must have 10 diameters straight pipe ahead of the meter and 5 diameters straight pipe after to insure proper flow through the meter.

4. The valves must be installed in the front and the back of the water meter.

 

This type of water meter can be used for a remote reading transmission system as equipped with a built-in sensor

 

WORKING PRINCIPLE

1. A changeover spring valve diverts flow to the appropriate meter, opening or closing according to pressure variations by changes in flow rate.

2. At low flow rate, the changeover valve closes and only the small meter in operation 2 water flows through the bypass meter, and the usage is recorded on its register.

3. When the flow rate increases, pressure is exerted on the large meter, until the flow rate reaches approximately one half the capacity of the bypass meter.

At this point, the drop in pressure causes the valve to open 1, and water flows through both the main meter and bypass meter, and the overall consumption is read by combining the main and bypass registers.

4. When flow is decreasing, the process in reversed. The valve is closed and water flows through the small meter.

 

Type

Size(mm)

Qs

Qp

Qt

Qmin

Min.

Max.

Max Flow

Nominal Flow

Transitional Flow

Min. Flow

Reading

Reading

m3/h

m3

LXF-50

50mm x 15mm

30

15

0.12

0.03

0.0001

999999+99999

LXF-80

80mm x 20mm

80

40

0.2

0.05

0.0001

999999+99999

LXF-100

100mm x 20mm

120

60

0.2

0.05

0.0001

999999+99999

LXF-150

150mm x 40mm

300

150

0.8

0.2

0.001

9999999+999999

LXF-200

200mm x 50mm

500

250

1.2

0.3

0.001

9999999+999999


MAXIMUM PERMISSIBLE ERROR ( ISO4064 CLASS B)

In the lower zone from Qmin inclusive up to but excluding Qt is±5%

In the upper zone from Qt inclusive up to and including Qs is ±2%


Please Attention:

1.If you want to get samples and catalogue from us, please contact us at info@yuy-precision.com  Normally, we need 7-15 days for making samples. and you need to pay for them. However, it would be highly appreciated if you can accept freight collect.
2.We normally need 20-35 days for production,however,please contact us if urgent
3.We ar OEM,ODM supplier,Wesupport FOB,CFR,DIF price term, and often ship from SHANGHAI or NINGBO sea port.
4.We encourage payment term:T/T or irrevocable L/C at sight, or 30% T/T deposit and 70% balance when receipt of advice of shipment.
5.Before installing the meter, we had better make sure that, it has been chosen correctly, check that the nominal diameter, flow rate, working temperature and pressure are compatible with the installation conditions.




BACK PREVIOUS NEXT

Contact


Enquiry